1.650.968.8848

1.650.968.8848  |  support@atilabiosystems.com

Power-Gene 9600 Plus Real-Time PCR System

Power-Gene 9600 Plus adopts Ferrotec specially-made Peltier, advanced fiber optic technology, new global wide-range power supply, the unique patented block dissipation technology and bottom detection mode, which provides better heating/cooling rate, temperature accuracy, uniformity and stability. Power-Gene 9600 Plus has up to 96 sample capacity and fast speed of dual-color scanning, and the design of 5 channel detection also covers the whole fluorescence detection wavelength.

This product is for research use only in the US.

Category: SKU: Power96

Power-Gene 9600 Plus Real-Time PCR System

The Power-Gene 9600 Plus has up to 96 sample capacity and fast speed of dual-color scanning, and the design of 5 channel detection also covers the whole fluorescence detection wavelength. Newly-designed automatic hot-lid without manual operation ensures constant pressure for various tube heights.

This auto hot-lid mode could be easily integrated into various automatic systems. Its Windows tablet computer and new touch screen brings excellent operating experience. Newly-improved Power-Gene 9600 Plus Real-Time PCR detection system can satisfy various clients’ requirement either for research or clinical use.

  • Novel and human-orientated running interface for smooth operation. User friendly interface with flexible programme setting and analysis and reporting using the stored parameters.
  • The adopted fluorescent real-time detection mode realizes simultaneous amplification and detection in the same tube without need of post experimental treatment.
  • Advanced thermoelectric technology ensures fast and steady heating and cooling of the ultra-fast heat cycling system. Multi-point temperature control ensures consistent temperature of 96 sample wells.
  • It uses maintenance-free long life LED excitation light source.
  • The advanced fiber optic transmission technology makes the photo-electric detection system very sensitive and reliable.
  • It has high linear range up to 10 orders of start DNA copies without serial dilution.

Real-time PCR (Polymerase Chain Reaction) instruments are essential tools in molecular biology and research laboratories for various applications. It allows for the quantification of DNA or RNA molecules present in a sample. The real-time monitoring of amplification allows researchers to gather data during the exponential phase of amplification, which increases the accuracy and sensitivity of the assay.

Real-time PCR instruments can be designed to perform multiplex reactions, allowing researchers to simultaneously amplify and quantify multiple target sequences in a single reaction. This saves time, reduces sample consumption, and allows for more comprehensive data collection. It is an essential tool for researchers studying molecular biology, genetics, genomics, and other related fields.

It allows them to study gene expression, analyze genetic variations, validate microarray data, and perform various functional analyses. In summary, real-time PCR instruments offer a range of benefits, including speed, accuracy, sensitivity, multiplexing capability, and suitability for various applications. They have become a fundamental tool in modern molecular biology and research, enabling scientists to gather valuable data and insights across a wide range of scientific disciplines.

Name PowerGene 9600 Plus
Model FQD-96A
Sample Capacity 96 x 0.2ml (Bottom Transparent)
Dynamics Range 1~1010 Copies
Excitation Wavelength 300~800nm
Emission Wavelength 500~800nm
Detected Fluorescence F1: FAM, SYBR Green I;
F2: VIC, HEX, TET, JOE, CY3, TAMRA;
F3: ROX, TEXAS-RAD;
F4: CY5, Quasar-670;
F5: CY5.5, Quasar-705
Block Temp. Range 4~105 ℃ (Minimum Increment: 0.1 ℃)
SOAK Low Temp. Conservation Function
Heating/Cooling Rate 4.0 ℃/s (max)
Temp. Control Accuracy ≤±0.1 ℃
Temp. Fluctuation ≤±0.1 ℃
Temp. Uniformity ≤±0.3 ℃
Temp. Control Mode Block/Tube Simulation Mode (Automatic Control Based On Sample Volume)
Sample Volume Range 5~100 µL
Gradient Temp. Range 1~36 ℃
Hot-lid Temp. Range 30~110 ℃ (Adjustable, Default 105 ℃, Automatic Hot-lid)
Fluorescence Detection Repeatability 5%
Scan Mode Entire Plate or Designated Line
Program Max 20 Segments for Each Program, Max 99 Cycles
Operation Mode Continuous
Scan Period 5.5s
Feature Function Absolute Quantification, Relative Quantification, SNP Analysis, Data Automatic Analysis,
Melting Curve Genotyping, Gradient, HRM, Multi-channel Crosstalk Correction, Background Correction,
Automatic Gain, Customized Parameters.
Operation System Microsoft, Windows XP/windows vista/windows 7/windows 8 Software, Excel 2000/2002/2003/2007/2012
PC Configuration Memory: 512M;
Hard Disk: 10GB;
CPU: Pentium® 4;
Virtual Memory: ≥1000MB
Power Supply 100-240V ~ 50/60Hz 600W
Dimensions (L×W×H) 410mm×386mm×352mm
Socket USB Adapter, Bluetooth Adapter
Authentication Ferrotec Pelitier/CE/MET/RoHS2/PICC Product Quality Liability Insurance
Tablet Microsoft Surface 2 Pro
SIMPLE. FAST. AFFORDABLE.

Please contact us for a quote or any questions about our Power-Gene 9600 Plus Real-Time PCR System.

Power-Gene 9600 Plus Real-Time PCR System
Sample Types

  • Urine specimens processed and tested with iAMP UISoluton Assay.
  • Direct urine specimens without any preservatives.Note: Clean-catch urine specimens are highly recommended.
  • Direct dry wound swab specimens collected by clinicians with Atila Swab Sample Collection Device (iAMP-SWA-SCD). Alternatively, specimens collected with sample collection devices from other vendors may be used after self-validation.
  • Wound swab specimens collected in transport medium (with sample collection devices from other vendors) may be used after self-validation.

Power-Gene 9600 Plus Real-Time PCR System
Sample Types

  • Vaginal/cervical swab collected as dry swabs or in 1X iAMP Sample Buffer.
  • Vaginal/cervical swab collected in commonly used transport medium.
  • First-void urine specimen without any preservatives.

Power-Gene 9600 Plus Real-Time PCR System
Sample Types

  • Vaginal/cervical swab collected as dry swabs or in 1X iAMP Sample Buffer, or in commonly used transport medium.
  • First-void urine specimen without any preservatives.
  • Ocular swab collected as dry swabs or in 1X iAMP Sample Buffer, or in commonly used transport medium.

Power-Gene 9600 Plus Real-Time PCR System
Assay Targets

  • Trichophyton spp.
  • Aspergillus
  • Curvularia spp.
  • Fusarium solani
  • Epidermophyton floccosum
  • Cryptococcus
  • Malassezia spp.
  • Sarocladium strictum
  • Scopulariopsis brevicaulis
  • Microsporum audouinii/canis
  • Alternaria
  • NeoScytalidim d/h
  • Geotrichum candidum
  • Candida spp.
  • Trichosporon
  • Neofusicoccum mangiferae

iAMP UISolution Assay for UTIs
Assay Targets

  • Acinetobacter baumannii
  • Citrobacter spp.
  • Enterobacter cloacae
  • Enterococcus spp.
  • Escherichia coli
  • Klebsiella aerogenes
  • Klebsiella oxytoca
  • Klebsiella pneumoniae
  • Morganella morganii
  • Proteus spp.
  • Providencia stuartii
  • Pseudomonas aeruginosa
  • Staphylococcus saprophyticus
  • Streptococcus agalactiae
  • Candida albicans
Pathogen TypeSpecies
BacteriaAcinetobacter baumannii
Anaerococcus spp
Bacteroides fragilis
Citrobacter spp.
Enterococcus spp.
Escherichia coli
Klebsiella oxytoca
Klebsiella pneumoniae
Proteus spp.
Pseudomonas aeruginosa
Serratia marcescens
Staphylococcus aureus
Staphylococcus epidermidis
Streptococcus agalactiae
Streptococcus pyogenes
VirusHerpes simplex virus 1
FungiCandida spp.
Candida glabrata
Candida krusei

Power-Gene 9600 Plus Real-Time PCR System
Assay Targets

  • Respiratory syncytial virus
  • Influenza A
  • Influenza B
  • SARS-CoV-2
  • Rhinovirus
  • Enterovirus
  • Coronavirus (229E, HKU1, OC43, NL63)
  • Parainfluenza virus (1-4)
  • Human adenovirus
  • Human bocavirus
  • Human metapneumovirus
  • Mycoplasma pneumonia
  • Klebsiella pneumonia
  • Bordetella parapertussis
  • Bordetella pertussis
  • Streptococcus pneumonia
  • Haemophilus influenzae
  • Legionella pneumophila
  • Chlamydia pneumonia
Detection Kit Species
ATWH CT/NG/TV/MG Detection Kit Chlamydia trachomatis
Trichomonas vaginalis
Mycoplasma genitalium
Neisseria gonorrhoeae
ATWH HSV 1/2 Detection Kit Herpes Simplex Virus type 1
Herpes Simplex Virus type 2
ATWH Candidiasis Detection Kit Candida albicans
Candida dubliniensis
Candida tropicalis
Candida parapsilosis
Candida glabrata
Candida krusei
ATWH MH Detection Kit Mycoplasma Hominis
ATWH Ureaplasma Detection Kit Ureaplasma urealyticum
Ureaplasma parvum
ATWH Bacterial Vaginosis Detection Kit Gardnerella vaginalis
Atopobium vaginae
Bacterial Vaginosis Associated Bacteria-2
Megasphaera-1
Megasphaera-2
ATWH Internal Control Detection Kit Homo Sapiens