1.650.968.8848

1.650.968.8848  |  support@atilabiosystems.com

iAMP RSV Detection Kit

This kit simultaneously detects RSV A and RSV B.

Each kit includes 100 tests.

This product is for research use only in the US.

Category: SKU: iAMP-RSV-100

iAMP RSV Detection Kit

Current detection of RSV mostly requires extraction of nucleic acids from the viruses for downstream detection. The iAMP RSV Detection Kit uses a simple, extraction-free workflow to deliver results in under 90 minutes. This kit is intended to detect both RSV A and B in a single assay from a single swab.

Respiratory syncytial virus, or RSV, is a common respiratory virus that infects lungs and respiratory tract. The virus usually causes cold-like symptoms but can be dangerous for infants and young children. According to CDC, at least 58,000 of children younger than 5 years are hospitalized each year due to RSV infection. RSV has also been associated with bronchiolitis and pneumonia in children.

Features Include

Fast Speed

From sample to answer is less than 90 minutes. Hands on times are less than 15 minutes per assay.

Easy To Use

Simple, extraction-free workflow that saves time and money.

Flexibility

Our kits can be used for detection of any number of samples without wasting extra reagents.

Low Cost

Price per assay is much better than any other kits on the market for detection of RSV targets.

Technical Specs

Assay Targets

RSV A, RSV B.

Reaction Time

Assay requires less than 1 hour of instrument time.

Sample Types

Nasopharyngeal/nasal swab collected as dry swabs or in 1X Elution Buffer or in commonly used transport medium.

Sensitivity

High sensitivity assay detects as low as 10 copies of pathogen genome per reaction.

Instruments

Compatible with Atila PowerGene 9600, Atila iAMP Personal Station 96, Bio-Rad CFX Maestro, ABI7500, and QuantStudio Real-Time PCR instruments, and other commonly used RT-qPCR instruments.

Workflow Overview for the iAMP RSV Detection Kit

This section is for demonstrative purposes only and may be incomplete or inaccurate. Always refer to the product instructions for precise guidelines and directions.

Dry swab in sample tube.
Add up to 1000 µL 1X iAMP Elution Solution (1XES).
Incubate at room temperature for 2 minutes.
Add 20 µL reaction mix and 5 µL processed sample.
Run on standard PCR instrument.
From sample to answer in less than 90 minutes.
SIMPLE. FAST. AFFORDABLE.

Please contact us for a quote or any questions about our iAMP Automatic Instrument.

iAMP RSV Detection Kit
Sample Types

  • Urine specimens processed and tested with iAMP UISoluton Assay.
  • Direct urine specimens without any preservatives.Note: Clean-catch urine specimens are highly recommended.
  • Direct dry wound swab specimens collected by clinicians with Atila Swab Sample Collection Device (iAMP-SWA-SCD). Alternatively, specimens collected with sample collection devices from other vendors may be used after self-validation.
  • Wound swab specimens collected in transport medium (with sample collection devices from other vendors) may be used after self-validation.

iAMP RSV Detection Kit
Sample Types

  • Vaginal/cervical swab collected as dry swabs or in 1X iAMP Sample Buffer.
  • Vaginal/cervical swab collected in commonly used transport medium.
  • First-void urine specimen without any preservatives.

iAMP RSV Detection Kit
Sample Types

  • Vaginal/cervical swab collected as dry swabs or in 1X iAMP Sample Buffer, or in commonly used transport medium.
  • First-void urine specimen without any preservatives.
  • Ocular swab collected as dry swabs or in 1X iAMP Sample Buffer, or in commonly used transport medium.

iAMP RSV Detection Kit
Assay Targets

  • Trichophyton spp.
  • Aspergillus
  • Curvularia spp.
  • Fusarium solani
  • Epidermophyton floccosum
  • Cryptococcus
  • Malassezia spp.
  • Sarocladium strictum
  • Scopulariopsis brevicaulis
  • Microsporum audouinii/canis
  • Alternaria
  • NeoScytalidim d/h
  • Geotrichum candidum
  • Candida spp.
  • Trichosporon
  • Neofusicoccum mangiferae

iAMP UISolution Assay for UTIs
Assay Targets

  • Acinetobacter baumannii
  • Citrobacter spp.
  • Enterobacter cloacae
  • Enterococcus spp.
  • Escherichia coli
  • Klebsiella aerogenes
  • Klebsiella oxytoca
  • Klebsiella pneumoniae
  • Morganella morganii
  • Proteus spp.
  • Providencia stuartii
  • Pseudomonas aeruginosa
  • Staphylococcus saprophyticus
  • Streptococcus agalactiae
  • Candida albicans
Pathogen TypeSpecies
BacteriaAcinetobacter baumannii
Anaerococcus spp
Bacteroides fragilis
Citrobacter spp.
Enterococcus spp.
Escherichia coli
Klebsiella oxytoca
Klebsiella pneumoniae
Proteus spp.
Pseudomonas aeruginosa
Serratia marcescens
Staphylococcus aureus
Staphylococcus epidermidis
Streptococcus agalactiae
Streptococcus pyogenes
VirusHerpes simplex virus 1
FungiCandida spp.
Candida glabrata
Candida krusei

iAMP RSV Detection Kit
Assay Targets

  • Respiratory syncytial virus
  • Influenza A
  • Influenza B
  • SARS-CoV-2
  • Rhinovirus
  • Enterovirus
  • Coronavirus (229E, HKU1, OC43, NL63)
  • Parainfluenza virus (1-4)
  • Human adenovirus
  • Human bocavirus
  • Human metapneumovirus
  • Mycoplasma pneumonia
  • Klebsiella pneumonia
  • Bordetella parapertussis
  • Bordetella pertussis
  • Streptococcus pneumonia
  • Haemophilus influenzae
  • Legionella pneumophila
  • Chlamydia pneumonia
Detection Kit Species
ATWH CT/NG/TV/MG Detection Kit Chlamydia trachomatis
Trichomonas vaginalis
Mycoplasma genitalium
Neisseria gonorrhoeae
ATWH HSV 1/2 Detection Kit Herpes Simplex Virus type 1
Herpes Simplex Virus type 2
ATWH Candidiasis Detection Kit Candida albicans
Candida dubliniensis
Candida tropicalis
Candida parapsilosis
Candida glabrata
Candida krusei
ATWH MH Detection Kit Mycoplasma Hominis
ATWH Ureaplasma Detection Kit Ureaplasma urealyticum
Ureaplasma parvum
ATWH Bacterial Vaginosis Detection Kit Gardnerella vaginalis
Atopobium vaginae
Bacterial Vaginosis Associated Bacteria-2
Megasphaera-1
Megasphaera-2
ATWH Internal Control Detection Kit Homo Sapiens